(+91) 7004326304CONTACT US
0item(s)

You have no items in your shopping cart.

Product was successfully added to your shopping cart.
sold

Lumis 100 VPAP S without humdifire

Be the first to review this product

Quick Overview

AirSense™ 10 CPAP

A comfortable start The AirSense 10 CPAP machine is designed to help you comfortably adjust to sleep apnea therapy. Featuring a sleek design and advanced comfort technology, the AirSense 10 CPAP machine will help you stay on track with your day-to-day sleep apnea therapy.
Key features

Press start and go. The AirSense 10 CPAP machine has been designed to make therapy easy. With no complicated settings or menus to navigate, simply press Start and you’re ready to go.

The quiet Easy-Breathe motor makes for a peaceful environment for you and your bed partner.

The user-friendly controls, intuitive interface and color LCD screen make it simple to navigate menus and customize comfort settings.

The SmartStart™ function begins your sleep apnea therapy as soon as you breathe into your mask. When you remove your mask, it stops automatically after a few seconds.

The built-in ambient light sensor adjusts to the brightness of the room. So if you need to get up during the night, the screen’s back light won’t disrupt your bed partner. The light also turns off automatically, so you can settle back to sleep without disturbance

sold by  VK


Regular Price: Rs.72,000.00

Special Price Rs.60,000.00

Availability: In stock

Details

TECHNICAL SPECIFICATIONS 90W power supply unit AC input range: 100–240V, 50–60Hz 1.0–1.5A, Class II 115V, 400Hz 1.5A, Class II (nominal for aircraft use) DC output: 24V 3.75A Typical power consumption: 53W (57VA) Peak power consumption: 104W (108VA) Environmental conditions Operating temperature: +41°F to +95°F (+5°C to +35°C) Note: The air flow for breathing produced by this therapy device can be higher than the temperature of the room. Under extreme ambient temperature conditions (104°F/40°C) the device remains safe. Operating humidity: 10 to 95% relative humidity, non-condensing Operating altitude: Sea level to 8,500' (2,591 m); air pressure range 1013 hPa to 738 hPa Storage and transport temperature: -4°F to +140°F (-20°C to +60°C) Storage and transport humidity: 5 to 95% relative humidity, non-condensing Electromagnetic compatibility The AirSense 10 complies with all applicable electromagnetic compatibility requirements (EMC) according to IEC60601-1-2:2007, for residential, commercial and light industry environments. It is recommended that mobile communication devices are kept at least 1 m away from the device. Information regarding the electromagnetic emissions and immunity of this ResMed device can be found on www.resmed.com, on the Products page under Service and Support. IEC 60601-1:2005 classification Class II (double insulation), Type BF, Ingress protection IP22. Sensors Pressure sensor: Internally located at device outlet, analog gauge pressure type, -5 to +45 cm H2O Flow sensor: Internally located at device inlet, digital mass flow type, -70 to +180 L/min Maximum single fault steady pressure Device will shut down in the presence of a single fault if the steady state pressure exceeds: 30 cm H2O for more than 6 sec or 40 cm H2O for more than 1 sec. Sound Pressure level measured according to ISO 17510-1:2007 (CPAP mode): SlimLine: 26.6 dBA with uncertainty of 2 dBA Standard: 26.6 dBA with uncertainty of 2 dBA Power level measured according to ISO 17510-1:2007 (CPAP mode): SlimLine: 34.6 dBA with uncertainty of 2 dBA Standard: 34.6 dBA with uncertainty of 2 dBA Declared dual-number noise emission values in accordance with ISO 4871:1996. Physical - device and water tub Dimensions (H x W x D): 4.57" x 10.04" x 5.91" (116 mm x 255 mm x 150 mm) Air outlet (complies with ISO 5356-1:2004): 22 mm Weight (device and standard water tub): 44 oz (1248 g) Weight (device and cleanable water tub): 44 oz (1248 g) Housing construction: Flame retardant engineering thermoplastic Water capacity: To maximum fill line 380 mL Standard water tub - material: Injection molded plastic, stainless steel and silicone seal Cleanable water tub - material: Injection molded plastic, stainless steel and silicone seal Temperature Maximum heater plate: 154°F (68°C) Cut-out: 165°F (74°C) Maximum gas temperature:  106°F ( 41°C) Air filter Standard: Material: Polyester non woven fiber Average arrestance: >75% for ~7 micron dust Hypoallergenic: Material: Acrylic and polypropylene fibers in a polypropylene carrier Efficiency: >98% for ~7-8 micron dust; >80% for ~0.5 micron dust Aircraft use ResMed confirms that device meets the Federal Aviation Administration (FAA) requirements (RTCA/DO-160, section 21, category M) for all phases of air travel. Wireless module Technology used: CDMA (USA and Canada only) 2G GSM (all regions except USA and Canada) FCC ID: 2ACHL-AIR10CD The AirSense 10 device complies with FCC Rules. The AirSense 10 device should be used at a minimum distance of 0.8" (2 cm) from the body during operation. Additional information regarding the FCC Rules for this device can be found on www.resmed.com. Operating pressure range AutoSet, AutoSet For Her, Elite, CPAP 4 to 20 cm H2O Supplemental oxygen Maximum flow: 4 L/min Pneumatic flow path 1. Flow sensor 2. Blower 3. Pressure sensor 4. Mask 5. Air tubing 6. Water tub 7. Device 8. Inlet filter

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

This is custom tab. You can add custom tab as an attribute for entire products, or for each categories. You can add CMS content such as sizing guide or videos to enhance product detail.