(+91) 7635050371 CONTACT US

0item(s)

You have no items in your shopping cart.

Product was successfully added to your shopping cart.
sold
Previous

Equinox EQ-NL 27 Compressor Nebulizer

Previous

Omron High Volume Nebulizer Compressor (NE-C25S) Nebulizer

AirStart™ 10 CPAP with HumidAir™ Heated Humidifier

Be the first to review this product

Quick Overview

The AirStart™ 10 CPAP Machine with HumidAir™ Heated Humidifier is an easy to use CPAP with basic, effective features users have come to enjoy on a nightly basis. Settings are easily accessed and changed on the color LCD display. At 2.75 pounds, this machine is also a great option for traveling.

sold by  VK


Rs.32,000.00

Availability: In stock

Details

Product Features The AirStart™ 10 CPAP is a basic, easy to use CPAP machine for those looking to add a second machine to a travel residence, or for those who prefer a machine with simplicity. The AirStart™ 10 includes comfort features such as built-in humidification and exhalation relief. Features Simplistic Menu LCD Color Display HumidAir™ Heated Humidifier Expiratory Pressure Relief (EPR™) Additional Comfort Features Compliance Data to SD Card LCD Color Display with Simplistic Menu The AirStart™ 10 CPAP is a simplified CPAP machine with basic features accessed through the machine's menu. From the display the user can adjust settings such a ramp, EPR, and humidity level. During therapy the display will show the current pressure and humidity level, before going black after a short period of time to avoid extra light in a dark room. Once therapy is completed, the usage hours are displayed. HumidAir™ Built-In Heated Humidifier The HumidAir™ Heated Humidifier is built-in to the AirStart™ 10 CPAP Machine to provide warmth and moisture to therapy air on a nightly basis, if desired. The water chamber attaches to the humidifier at the side of the machine and is easily taken out and apart for filling and cleaning. The machine menu features a warm up option to preheat the humidifier so that it is warm at the onset of therapy. If using the AirStart™ 10 CPAP without the heated humidifier, the Side Cover for AirSense™ 10, AirStart™ 10, and AirCurve™ 10 Machines (not included) must be installed at the end of the machine in place of the water chamber. EPR™ & Additional Comfort Features The AirStart™ 10 CPAP includes comfort features that users have come to expect and rely on. Expiratory Pressure Relief (EPR™) allows a drop in pressure for easier exhalation. Ramp allows an increase to prescribed pressure over a set amount of time at the beginning of a therapy session. Compliance Data to SD Card The AirStart™ 10 CPAP records basic compliance data to the included SD card. The SD card can be removed and given to a physician for therapy tracking. Specifications This Product Includes... AirStart 10 CPAP Machine Built-In HumidAir Heated Humidifier Standard Water Chamber Standard 19mm Tubing SD Card (Installed) 1 - Standard Filter (Installed) Power Supply and Cord Travel Bag User Guide Product Specifications Weight - Machine with Water Chamber: 2.53 lbs (40.5 oz.) Dimensions - Machine with Water Chamber: 10.04 in L x 4.57 in W x 5.91 in H Weight - Standard Chamber: .54 lb Weight - Machine with optional Side Cover (Without Water Chamber): Approx. 2.452 lbs Dimensions - Machine with optional Side Cover (Without Water Chamber): Approx. 8 in L x 4.57 in W x 5.91 in H Dimensions - Travel Bag: 13.24 in L x 10 in W x 5 in H Weight - Travel Bag Alone: 1.18 lb Weight - Machine with Humidifier; Power Supply and Cord; Standard Tube; Travel Bag: Approximately 5.1 lbs Sound Level: 26.6 dBA Water Chamber Capacity: 380 mL Weight - 90W Power Supply, Cord and Plug: 1.29 lb Dimensions - 90W Power Supply Only (Not including Cor or Plug): 5 1/2 in x 1 7/8 in x 1 1/4 in AC Input Range - 90W Power Supply: 100 - 240V, 50 - 60Hz, 1.0 - 1.5A, Class II DC Output - 90 W Power Supply: 24V --- 3.75A Typical Power Consumption: 53W (57VA) Peak Power Consumption: 104W (108VA) Operating Pressure: 4 - 20 cm H2O (0.2 cm increments) Length - Standard Tubing: 6.5 Feet Materials - Standard Tubing: Flexible Plastic Materials - Water Chamber: Injection Molded Plastic, Stainless Steel, Silicone Seal Materials - Standard Filter: Polyester non-woven fiber Operating Temperature: 41° F - 95° F (5° C - 35° C) Storage and Transport Temperature: -4° F - 140° F (-20° C - 60° C) Operating Humidity: 10% - 95% Relative Humidity, non-condensing Storage and Transport Humidity: 5% - 95% relative Humidity, non-condensing Operating Altitude: Sea Level - 8500 Feet (2,591 M); Air pressure range 1013 hPa - 738 hPa Maximum Temperature - Heating Plate: 154° F (68° C) Maximum Temperature - Cut Out: 165° F (74° C) Maximum Gas Temperature: Less than or Equal to 106° F (? 41° C) IEC 60601-1:2005 Classification: Class II (Double Insulation), Type BF, Ingress protection IP22 Machine Warranty: 2 Years Patient Weight: Greater than 66 lbs Cleaning Instructions The chamber should be taken apart and hand washed weekly using warm water and a mild detergent. It should be rinsed well and allowed to air dry out of direct sunlight before reassembling. The chamber should not be washed in a dishwasher or washing machine. The SlimLine hose should be washed in the same manner and allowed to completely dry out of direct sunlight before reattaching to the machine and mask. Required Settings: 1 Pressure Setting is Required Unless directed otherwise, CPAP.com will leave this machine at its default settings of: Ramp: 20 mins Start Pressure: 4 cm H2O Humidity Level: 4 Mask Type: Pillows EPR: Off Important Tips FAA Compliance Letter: To view the FAA compliance letter for the AirStart™ 10 CPAP with HumidAir™ Heated Humidifier, click here. Humidifier Tips Do not fill the water chamber past the max fill line as this could result in water entering and damaging the device. Allow the water chamber to cool for ten minutes after use before handling as it could be too hot to the touch. The machine will display a blue snowflake in the upper right of the screen while cooling is taking place. The water chamber should be washed weekly using warm water and a mild detergent, rinsed well, and allowed to dry out of direct sunlight. The standard water chamber included is not dishwasher safe and should only be hand washed. To view a dishwasher safe chamber, see the Dishwasher Safe Water Chamber for AirStart™ 10 Humidair™ Heated Humidifier. Purchase the Side Cover for AirSense™ 10, AirStart™ 10, and AirCurve™ 10 Machines separately in order to enclose the machine opening when the water chamber has been removed. This is only required if the integrated heated humidifier is not being used. How to Determine if the Water Chamber is Dishwasher Safe? AirStart™ 10, AirSense™ 10, and AirCurve™ 10 machines denote the water chamber model with an "S" or "C" label. Look directly above the maximum fill line located on the side of the chamber to find the word HumidAir™ and the corresponding letter embossed into the tank. If the water chamber is dishwasher safe, the chamber will appear as HumidAir C, which represents a cleanable tank. If the water chamber is the standard model, the chamber will appear as HumidAir S, which represents a standard tank. Hose Tips Either a 15mm (Slim) hose or a 22mm (Standard) hose may be used with the AirStart™ 10 machine. The machine must be changed to the proper setting to ensure accurate therapy pressure. A standard (19mm) hose is included with the purchase of the AirStart™ 10 CPAP machine. The hose is found in the interior, zipped compartment of the travel bag. The zippered nook is located at the point where the cover meets the bottom of the travel bag at the back of the machine compartments. SD Card Location The included SD card comes installed in the machine ready to use. While looking at the machine with the display facing forward, the SD card is located under the upper flap with the blue "SD" logo on the left side of the machine. Features Summary for the AirSense Line of Machines AirStart™ 10 CPAP Machine with HumidAir™ Heated Humidifier: Basic, single pressure CPAP machine with EPR™, ramp, and humidity controls only. Records basic compliance data to SD card. Only available in black. ResMed AirSense 10 CPAP Machine with HumidAir™ Heated Humidifier: Single pressure CPAP machine with included HumidAir Humidifier. Can be set only in CPAP mode and CPAP mode with EPR. Compliance sleep data along with AHI. Only available in black. AirSense 10 Elite CPAP Machine with HumidAir™ Heated Humidifier: Single pressure CPAP machine with included HumidAir Humidifier. Can be set only in CPAP mode and CPAP mode with EPR. Compliance sleep data plus advanced data on the screen. Only available in black. AirSense 10 AutoSet CPAP Machine with HumidAir™ Heated Humidifier: Auto-adjusting CPAP machine with standard AutoSet algorithm with included HumidAir Humidifier. Can be set in Auto mode with standard AutoSet algorithm, Auto mode with standard AutoSet algorithm with EPR, CPAP mode and CPAP mode with EPR. Only the standard AutoSet algorithm is available on this machine. Compliance sleep data plus advanced data on the screen. Only available in black. AirSense 10 AutoSet for Her CPAP Machine with HumidAir™ Heated Humidifier: Auto-adjusting CPAP machine with standard AutoSet algorithm with included HumidAir Humidifier. Can be set in AutoSet For Her algorithm OR standard AutoSet algorithm , Auto mode, Auto mode with EPR, CPAP mode and CPAP mode with EPR. Compliance sleep data plus advanced data on the screen. Only available in white. Manufacturer Warranty Return On Warranty Issues Only

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

This is custom tab. You can add custom tab as an attribute for entire products, or for each categories. You can add CMS content such as sizing guide or videos to enhance product detail.